Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
JAMA Netw Open ; 5(1): e2142210, 2022 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-34994793

RESUMO

Importance: A surge of COVID-19 occurred from March to June 2021, in New Delhi, India, linked to the B.1.617.2 (Delta) variant of SARS-CoV-2. COVID-19 vaccines were rolled out for health care workers (HCWs) starting in January 2021. Objective: To assess the incidence density of reinfection among a cohort of HCWs and estimate the effectiveness of the inactivated whole virion vaccine BBV152 against reinfection. Design, Setting, and Participants: This was a retrospective cohort study among HCWs working at a tertiary care center in New Delhi, India. Exposures: Vaccination with 0, 1, or 2 doses of BBV152. Main Outcomes and Measures: The HCWs were categorized as fully vaccinated (with 2 doses and ≥15 days after the second dose), partially vaccinated (with 1 dose or 2 doses with <15 days after the second dose), or unvaccinated. The incidence density of COVID-19 reinfection per 100 person-years was computed, and events from March 3, 2020, to June 18, 2021, were included for analysis. Unadjusted and adjusted hazard ratios (HRs) were estimated using a Cox proportional hazards model. Estimated vaccine effectiveness (1 - adjusted HR) was reported. Results: Among 15 244 HCWs who participated in the study, 4978 (32.7%) were diagnosed with COVID-19. The mean (SD) age was 36.6 (10.3) years, and 55.0% were male. The reinfection incidence density was 7.26 (95% CI: 6.09-8.66) per 100 person-years (124 HCWs [2.5%], total person follow-up period of 1696 person-years as time at risk). Fully vaccinated HCWs had lower risk of reinfection (HR, 0.14 [95% CI, 0.08-0.23]), symptomatic reinfection (HR, 0.13 [95% CI, 0.07-0.24]), and asymptomatic reinfection (HR, 0.16 [95% CI, 0.05-0.53]) compared with unvaccinated HCWs. Accordingly, among the 3 vaccine categories, reinfection was observed in 60 of 472 (12.7%) of unvaccinated (incidence density, 18.05 per 100 person-years; 95% CI, 14.02-23.25), 39 of 356 (11.0%) of partially vaccinated (incidence density 15.62 per 100 person-years; 95% CI, 11.42-21.38), and 17 of 1089 (1.6%) fully vaccinated (incidence density 2.18 per 100 person-years; 95% CI, 1.35-3.51) HCWs. The estimated effectiveness of BBV152 against reinfection was 86% (95% CI, 77%-92%); symptomatic reinfection, 87% (95% CI, 76%-93%); and asymptomatic reinfection, 84% (95% CI, 47%-95%) among fully vaccinated HCWs. Partial vaccination was not associated with reduced risk of reinfection. Conclusions and Relevance: These findings suggest that BBV152 was associated with protection against both symptomatic and asymptomatic reinfection in HCWs after a complete vaccination schedule, when the predominant circulating variant was B.1.617.2.


Assuntos
COVID-19/epidemiologia , Pessoal de Saúde , Reinfecção , SARS-CoV-2 , Adulto , COVID-19/etiologia , COVID-19/prevenção & controle , Vacinas contra COVID-19/administração & dosagem , Estudos de Coortes , Feminino , Humanos , Imunogenicidade da Vacina , Índia/epidemiologia , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários , Centros de Atenção Terciária , Vacinas de Produtos Inativados/administração & dosagem , Vírion/imunologia , Adulto Jovem
2.
Bull World Health Organ ; 98(3): 206-211, 2020 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-32132755

RESUMO

PROBLEM: Rapid growth in the use of medical devices has drawn attention to gaps in the systematic monitoring of medical device-associated adverse events in India. APPROACH: Implementation of national regulations on medical devices started in January 2018. Supported by a nationwide network of monitoring centres, the Indian Pharmacopoeia Commission coordinates adverse event reports from manufacturers, legal representatives and patients or users. The commission follows-up and reviews reports with subject expert groups and sends recommendations on necessary action to the national regulatory authority. LOCAL SETTING: Before 2015, no systematic structure was in place to collate adverse events associated with medical devices. Several reports of deaths and hospitalization due to faulty hip implants, cardiac stents and poor-quality devices prompted the health ministry to launch the materiovigilance programme. RELEVANT CHANGES: From July 2015 to October 2019, the commission received 1931 adverse event reports, mostly from marketing authorization holders; 1277 were serious events. Reporting increased markedly after 2017. Cardiac stents were the most reported device (926 events; 47.95%). To encourage a culture of reporting, the commission has raised awareness about the programme among stakeholders, developed user-friendly reporting tools and guidelines, and conducted training for hospital personnel on medical device adverse event reporting. LESSONS LEARNT: Regular training to stakeholders develops a sense of responsibility towards reporting medical device adverse events and ensures quality data reporting. Reporters must be assured that reporting adverse events does not have any legal implications for them and given acknowledgement of their role in high-quality device associated adverse event reporting.


Assuntos
Equipamentos e Provisões/efeitos adversos , Equipamentos e Provisões/estatística & dados numéricos , Gestão da Segurança/estatística & dados numéricos , Segurança de Equipamentos , Humanos , Índia , Notificação de Abuso , Vigilância de Produtos Comercializados , Sistema de Registros , Gestão da Segurança/legislação & jurisprudência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...